Tin Tetrachloride, Anhydrous Chemical Storage Specifications

Compliant storage and rental solutions for Tin Tetrachloride, Anhydrous (SnCl4). EPA, OSHA, and NFPA guidance for containment, segregation, and fire protection — with rental buildings matched to this material.

Non-flammableNon-Flammable Storage

Chemical formula

About Tin Tetrachloride, Anhydrous

It is a colorless hygroscopic liquid, which fumes on contact with air. It is used as a precursor to other tin compounds. It was first discovered by Andreas Libavius (1550–1616) and was known as spiritus fumans libavii. Tin(IV) chloride. Anhydrous Tin(IV) chloride.

Structured hazard data

Hazard class
See SDS
Storage category
Non-Flammable Storage
Flammable
No
Flash point
See SDS
Storage temperature
Ambient
Recommended extinguishing agent
Dry Chemical
Compatibility / segregation
Incompatible Materials Acids, Strong oxidizing agents, Strong bases, Alcohols, Metals

Acute Inhalation Toxicity - Vapors Category 2 Skin Corrosion/Irritation Category 1 B Serious Eye Damage/Eye Irritation Category 1 Specific target organ toxicity (single exposure) Category 3

Fire Suppression System

Dry Chemical fire suppression is recommended for Tin Tetrachloride, Anhydrous

  • Water

    Water

  • Dry Chemical

    Dry Chemical · Recommended

  • CO₂ / Other

    CO₂ / Other

Guidance: Dry Chemical fire suppression is generally recommended for Tin Tetrachloride, anhydrous (SnCl4). *Please consult your raw material manufacturer's safety data sheet (SDS) and your local authority having jurisdiction to verify the most adequate fire suppression extinguisher for your specific storage or use.

Additional extinguishing notes: Suitable Extinguishing Media Use extinguishing measures that are appropriate to local circumstances and thesurrounding environment

Always confirm extinguishing agents against the manufacturer SDS and your authority having jurisdiction before specifying a rental building fire-suppression package.

Storage & segregation guidance

Compliant storage and rental solutions for Tin Tetrachloride, anhydrous should account for its listed hazards, climate control needs (Ambient), and segregation requirements. Incompatible Materials Acids, Strong oxidizing agents, Strong bases, Alcohols, Metals

Review Segregated storage for incompatible chemicals and How the NFPA 704 hazard rating works when designing fire rating, containment, and building selection.

Properties: Melting Point/Range -33 °C / -27.4 °F Boiling Point/Range 114 °C / 237.2 °F

Matched to this chemical

Recommended storage solutions for Tin Tetrachloride, Anhydrous

Fire rating, footprint, and containment options from the US Hazmat Rentals fleet — sized for compliant chemical storage.

  • Non-fire-rated0 HourChemical Storage Shipping

    BoxSAFE CX

    • Non Fire-Rated
    • 8 ft x 40 ft x 8' 5"
    • 50 Qty 55 Gallon Drums
    • 9 Pallets or Totes
    • 302 Square Feet storage
    View product
  • Non-fire-rated0 HourChremical Storage

    Non Fire-Rated

    • 0-Hour Fire-Rated
    • 8 ft x 40 ft
    • 57 Barrels
    • 55 Gal Storage Drums
    View product
  • Non-fire-rated0 HourChremical Storage

    Non Fire-Rate

    • 0-Hour Fire-Rated
    • 8 ft x 20 ft
    • 27 Barrels
    • 55 Gal Storage Drums
    View product

Material handling

How do you manage your bulk chemical storage?

US Hazmat Rentals buildings are designed around the primary storage formats teams use in the field — each path opens the matching storage solution on ushazmatrentals.com.

We have solutions designed for your workflow process needs.

Frequently asked questions

How should Tin Tetrachloride, anhydrous be stored?

Store Tin Tetrachloride, anhydrous in EPA-, OSHA-, and NFPA-compliant containment suited to its hazards (Consult the SDS and applicable hazard classification). Climate range guidance: Ambient. Compatibility notes: Incompatible Materials Acids, Strong oxidizing agents, Strong bases, Alcohols, Metals US Hazmat Rentals provides compliant chemical storage buildings available for rental.

Is Tin Tetrachloride, anhydrous flammable?

Tin Tetrachloride, anhydrous is not flagged as flammable in this database (No). Still verify the SDS and store in compliant containment for its listed hazard class.

What hazard class is Tin Tetrachloride, anhydrous?

Tin Tetrachloride, anhydrous is listed as: Consult the SDS and applicable hazard classification. Acute Inhalation Toxicity - Vapors Category 2 Skin Corrosion/Irritation Category 1 B Serious Eye Damage/Eye Irritation Category 1 Specific target organ toxicity (single exposure) Category 3

What fire suppression is recommended for Tin Tetrachloride, anhydrous?

Dry Chemical fire suppression is generally recommended for Tin Tetrachloride, anhydrous (SnCl4). *Please consult your raw material manufacturer's safety data sheet (SDS) and your local authority having jurisdiction to verify the most adequate fire suppression extinguisher for your specific storage or use.

Is compliant Tin Tetrachloride, anhydrous storage available for rent?

Yes. US Hazmat Rentals offers EPA-, OSHA-, and NFPA-compliant chemical storage buildings and containment that can be matched to Tin Tetrachloride, anhydrous. Request sizing and compliance guidance at https://ushazmatrentals.com/chemical-storage-quote-request/.